CE & RoHS Tested · SGS-Assessed Supplier · OEM/ODM from 10 pcs info@favreauelectric.com
Yueqing Favreau Electric Co., Ltd.

Dual Power Automatic Transfer Switch (ATS) Solutions

Engineered for seamless power transition between grid, diesel generators, and PV hybrid inverters. Certified to IEC 60947-6-1 standard for maximum power reliability.

CE · RoHS CertifiedPC Class & CB ClassTransfer Time < 50msOEM/ODM MOQ 10 Pcs
Get Catalog Explore ATS Models
2018Established Year
<50msAverage Transfer Speed
4.6/5Verified Buyer Score
91%Response Rate
#7Top ATS Supplier Rank*
Technical Masterclass & Buyer Guide

Dual Power Automatic Transfer Switch (ATS) Sourcing, Future Trends & System Selection

An in-depth technical analysis for electrical engineers, panel builders, and global procurement buyers evaluating power transition infrastructure for critical distribution boards.

1. Demystifying the Dual Power Automatic Transfer Switch (ATS)

A Dual Power Automatic Transfer Switch (ATS) is an essential safety and switching component installed in low-voltage distribution systems. Its primary function is to continuously monitor primary electrical sources (such as the main utility grid) and automatically transfer connected critical electrical loads to a secondary backup source (such as a diesel generator, energy storage system, or auxiliary grid line) whenever the primary source fails, drops below threshold voltages, or suffers phase loss.

In modern industrial, commercial, and residential electrical networks, unexpected power outages can lead to severe data loss, equipment failure, and costly operational downtime. A precision-built Dual Power Automatic Transfer Switch ensures power continuity by performing automated source detection, mechanical interlocking, arc quenching, and contact transfer—all within a fraction of a second. Once main utility power is restored to nominal levels, the ATS automatically performs a reverse transfer, reconnecting the load to the primary supply and signaling the backup power unit to shut down safely.

Information Gain Note for Technical Specifiers:

When specifying an ATS under IEC 60947-6-1 standards, buyers must distinguish between PC Class ATS (built exclusively for switching without integral overcurrent trips, offering high short-circuit withstand current $I_{cw}$) and CB Class ATS (built with dual miniature or molded-case circuit breakers containing thermal-magnetic trip units). Choosing the correct class prevents nuisance tripping and guarantees structural integrity during high-fault conditions.

Essential Technical Terminology for Sourcing Managers:

  • Transfer Time ($t_t$): The physical duration from the opening of the main contact set to the closing of the backup contact set. Favreau ATS units achieve transfer speeds between 8ms and 50ms.
  • Rated Operational Current ($I_e$): The continuous current rating (ranging from 16A up to 125A in Din-rail MCB types, and 100A to 630A in frame types) without overheating contacts.
  • Rated Short-Time Withstand Current ($I_{cw}$): The peak thermal and mechanical stress a PC Class ATS can handle during a downstream short circuit without contact welding or mechanical deformation.
  • Mechanical Interlock: A physical blocking mechanism preventing both power contacts from closing simultaneously, eliminating the risk of out-of-phase power backfeeding.
Favreau ATS Product Portfolio

Best-Selling Dual Power Automatic Transfer Switches

Explore our export-ready, CE-certified dual power switching range engineered by Yueqing Favreau Electric Co., Ltd.

2. Global Future Development Trends in Dual Power ATS Technology (2025–2030)

As electrical grids transition toward decentralized renewable energy generation and microgrids, the requirements placed upon Dual Power Automatic Transfer Switches are rapidly changing. Procurement buyers must align their supply chains with these three key technology trends:

Trend 1: Solar-Storage-Grid Tri-Source & Inverter Priority Switching

Traditional ATS designs focused strictly on Grid-to-Generator (Main-to-Emergency) transfers. Today’s green energy ecosystems demand intelligent transfer switches capable of handling Solar PV Inverters, Battery Energy Storage Systems (BESS), and Main Utility Grids. Modern ATS units produced by Yueqing Favreau Electric Co., Ltd. feature priority logic inputs, enabling users to prioritize clean solar energy during peak sunshine hours and automatically switch to utility power or diesel generators only when battery state-of-charge (SoC) limits are reached.

Trend 2: Ultra-Fast Solid-State & Hybrid Arc-Quenching Contactors

Standard mechanical changeover switches experience electric arc erosion during switching under heavy inductive loads. Future ATS architectures are incorporating hybrid arc-quenching technology and electromagnetic drive mechanisms. By reducing total transfer times below 15 milliseconds, modern ATS units eliminate voltage sags during transfers, keeping sensitive IoT servers, medical devices, and telecom equipment fully operational without requiring massive inline UPS units.

Trend 3: Smart IoT Integration, RS485 Modbus, and Predictive Maintenance

Commercial building operators and industrial plant managers no longer accept passive electrical hardware. Contemporary dual power transfer switches are increasingly equipped with RS485 Modbus RTU communication interfaces or wireless IoT modules (such as Tuya / Smart Life protocols). This allows real-time telemetry monitoring of phase voltages, load current, frequency, contact temperature, and switching cycle counters directly on central SCADA systems or mobile applications.

3. Evolving Procurement Trends for International B2B Buyers

For importers, electrical wholesalers, and switchboard panel builders across Europe, the Middle East, Southeast Asia, and the Americas, sourcing low-voltage power equipment requires navigating shifting regulatory and logistical landscapes:

  • Demand for Compact Din-Rail Form Factors: Space inside distribution panels is at a premium. Modern installers prefer compact, modular DIN-rail mounted ATS devices (such as Favreau's 2P and 4P MCB-type dual power switches) over bulky traditional motorized changeover switches.
  • Multi-Standard Compliance (CE, RoHS, IEC 60947-6-1): Strict customs inspections require comprehensive compliance. Overseas buyers demand verified test reports for electromagnetic compatibility (EMC) and low-voltage directives (LVD).
  • Flexibility in OEM Parameters & White-Label Packaging: Global grid voltages vary significantly—from 110V/220V single-phase systems in Latin America to 230V/400V 50Hz systems in Europe and Africa. Importers need manufacturing partners who can easily customize trip thresholds, contact delay timers, and brand packaging at low Minimum Order Quantities (MOQ).
Technical Decision Matrix

PC Class vs CB Class Dual Power ATS Selection Guide

Use this technical comparison matrix to select the optimal transfer switch for your project panel requirements.

Parameter / Feature PC Class Dual Power ATS CB Class Dual Power ATS Favreau Recommendation
Internal Structure Electromagnetic contact system without thermal trip mechanisms. Dual integrated circuit breakers (MCB/MCCB) with trip units. PC Class for mission-critical uninterrupted transfer; CB Class for space-saving panel boards.
Overload & Short-Circuit Protection Requires upstream fuses or external circuit breaker protection. Built-in thermal-magnetic overcurrent protection on both lines. Use CB Class when branch circuit breaker space is limited inside the consumer unit.
Short-Time Withstand ($I_{cw}$) Exceptionally high short-time withstand rating ($I_{cw}$ up to 10kA+). Limited by the short-circuit breaking capacity ($I_{cn}$) of internal breakers. PC Class is superior for high fault current industrial supply lines.
Transfer Speed Range Ultra-fast mechanical transition (<8ms to 30ms). Standard motorized / lever transition (30ms to 100ms). Specify Favreau Fast PC ATS for IT networks and hospital backup circuits.
Ideal Application Field Hospitals, data centers, telecom towers, solar PV energy storage. Residential distribution boxes, commercial lighting panels, small workshops. Consult Favreau engineers with your Single Line Diagram (SLD).
Enterprise Strength

Why Global Importers Partner with Yueqing Favreau Electric Co., Ltd.

Based in China's low-voltage electrical capital, Yueqing Favreau Electric Co., Ltd. combines advanced manufacturing automation with strict quality control.

Yueqing Favreau Electric Co., Ltd. Factory Overview
Favreau Production Line Workshop
SGSAssessed Supplier
OEM & ODM Excellence

Precision Electrical Manufacturing from Yueqing

Yueqing Favreau Electric Co., Ltd. is located in the Sulu Industrial Zone of Yueqing, Wenzhou—China's premier manufacturing hub for low-voltage electrical components. Our modern facility integrates R&D engineering, automated production lines, quality inspection workshops, and global export services.

We specialize in manufacturing Dual Power Automatic Transfer Switches (ATS), Din-rail voltage protectors, DC solar circuit breakers, surge protective devices (SPD), smart WiFi breakers, and energy meters. Our factory operates under strict ISO 9001 quality management guidelines, with product lines certified for CE and RoHS compliance.

  • Established 2018: Verified production workshop & warehouse
  • 100% Function Testing: High-voltage dielectric & transfer time verification
  • Low MOQ OEM (10 Pcs): Private labeling, custom laser marking & boxes
  • SGS Audited Premises: Full inspection reports available for B2B buyers
Automated Testing & Quality Inspection at Favreau Electric
Automated Quality Inspection & Testing Stations
Certified Electrical Components Workshop
CE & RoHS Certified Component Assembly
Finished Product Packaging Warehouse
Export Logistics & Warehouse
Favreau Electrical Engineering Laboratory
Favreau R&D Testing Lab
Surface Mount Technology SMT Line
High-Precision SMT Placement Line
Frequently Asked Questions

Dual Power Automatic Transfer Switch (ATS) Sourcing FAQ

Answers to common technical queries asked by electrical contractors, engineers, and international sourcing teams.

What is the difference between PC Class and CB Class Dual Power Automatic Transfer Switches?

The main operational difference lies in short-circuit protection and internal contact design:

  • PC Class ATS: Built specifically to switch power contacts under normal and fault conditions. It does not feature integral overcurrent trip units, allowing it to withstand high short-time fault currents ($I_{cw}$) without tripping. Upstream circuit breakers or fuses must be installed.
  • CB Class ATS: Incorporates dual circuit breakers equipped with thermal-magnetic or electronic trip units. It provides both power source switching and downstream short-circuit/overload protection in a single integrated chassis.
How fast does a Favreau Dual Power Automatic Transfer Switch change power sources?
Our MCB-type dual power transfer switches feature total switching times under 30 milliseconds, while our specialized PC Class electromagnetic switches achieve rapid transfer speeds between 8ms and 20ms. This ultra-fast transition ensures continuous power for computers, servers, lighting, and communication infrastructure without causing device reboots.
Can a Dual Power ATS be used to switch between a Solar Inverter and Utility Grid?
Yes. Dual Power ATS units are ideal for solar PV hybrid systems. In standard configurations, Solar/Inverter AC output is wired to Source A (Primary), and Main Utility Grid power is wired to Source B (Secondary). When battery voltage drops below a set threshold, the ATS automatically switches connected loads to grid power, returning to solar power once battery charging resumes.
Why is a 4-Pole (4P) ATS required instead of a 3-Pole (3P) ATS in certain installations?
A 4-Pole ATS switches all three phase conductors (L1, L2, L3) as well as the Neutral conductor (N). A 4P switch is mandatory in installations with separate earthing systems (such as TT earthing networks), dual-utility power feeds, or when standby generator neutral isolation is required by national wiring standards to prevent stray ground currents and nuisance RCD/GFCI tripping.
What OEM customization options does Yueqing Favreau Electric Co., Ltd. offer for ATS products?
We offer extensive OEM/ODM white-label customization for orders starting at just 10 pieces. Customization options include: custom rated operational voltages (110V, 220V, 230V, 380V, 400V, 440V at 50Hz/60Hz), custom over/under voltage delay timers, laser-etched brand logos, customized terminal terminal markings, specialized user manuals, and private-label retail boxes.
What certifications and test reports accompany Favreau ATS shipments?
Every ATS model manufactured by Yueqing Favreau Electric Co., Ltd. holds valid CE and RoHS compliance certificates. Furthermore, our manufacturing facility undergoes regular onsite verification and assessment by SGS Group. Certificate copies, laboratory EMC/LVD test reports, and factory inspection documentation are available upon request prior to order placement.

*Rankings and shipment figures are based on Alibaba.com supplier ranking and 180-day transaction data at the time of publishing.

Streamline Your ATS Procurement with Favreau

Contact our application engineers for technical datasheets, CAD drawings, sample orders, and direct factory pricing. Email: info@favreauelectric.com

Get Catalog